{"_buckets": {"deposit": "bf21efc9-8e5a-47a5-b094-cf236f5b3153"}, "_deposit": {"created_by": 4, "id": "291", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "291"}, "status": "published"}, "_oai": {"id": "oai:uekusa.repo.nii.ac.jp:00000291", "sets": ["1", "63"]}, "author_link": ["495", "496", "497", "498", "499"], "control_number": "291", "item_3_biblio_info_12": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-03-01", "bibliographicIssueDateType": "Issued"}, "bibliographicNumberOfPages": "159", "bibliographicPageEnd": "127", "bibliographicPageStart": "121", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "植草学園大学研究紀要", "bibliographic_titleLang": "ja"}, {"bibliographic_title": "Bulletin of Education and Health Sciences, Uekusa-Gakuen University", "bibliographic_titleLang": "en"}]}]}, "item_3_description_10": {"attribute_name": "抄録(日)", "attribute_value_mlt": [{"subitem_description": "近年,筋電,眼電,脳波などの生体信号を利用した入力デバイスが市販されている。それらが福祉機器の入力デバイスとして利用できれば,障害(児)者が入力デバイスを選定する選択肢が広がり,また社会福祉予算の効率的,効果的な活用が期待できる。本研究は,市販の生体信号入力デバイスを対象とし,障害(児)者を対象とした入力デバイスとしての適応の可能性を評価した。評価の実施には入力手段として咬合動作による筋電,眼球の外転,内転による眼電,脳波の3種類を対象とし,健常成人4名を被験者とした。結果として,3種類の入力手段のうち咬合動作による筋電については有効であった。一方眼電,脳波についての適応は困難だった。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}]}, "item_3_description_11": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "In recent years, some input devices using biological signals - Electro Myogram (EMG), Electro Oculogram (EOG) and Electro Encephalogram (EEG) have become commercially available. There are indications that commercial use of these devices has great potential to increase the options of persons with disabilities as well as efficiently and effectively make use of the social welfare budget. We evaluated the feasible adaptability of one particular device as an assistive device for these individuals. Operation of the 3 biological input methods of the device – EMG, EOG and EEG was evaluated by 4people with non-disabilities. The results of the evaluation indicated that the input device using EMG had potential use as an assistive input device, while, those using EOG and EEG did not.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_3_description_15": {"attribute_name": "表示順", "attribute_value_mlt": [{"subitem_description": "15", "subitem_description_type": "Other"}]}, "item_3_description_16": {"attribute_name": "アクセション番号", "attribute_value_mlt": [{"subitem_description": "KJ00008523520", "subitem_description_type": "Other"}]}, "item_3_source_id_1": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12412714", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_19": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "18835988", "subitem_source_identifier_type": "PISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "open access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_abf2"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAlternatives": [{"creatorAlternative": "MIYASAKA, Tomoya", "creatorAlternativeLang": "en"}], "creatorNames": [{"creatorName": "宮坂, 智哉", "creatorNameLang": "ja"}, {"creatorName": "MIYASAKA, Tomoya", "creatorNameLang": "en"}], "familyNames": [{"familyName": "ミヤサカ", "familyNameLang": "ja"}], "givenNames": [{"givenName": "トモヤ", "givenNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "495", "nameIdentifierScheme": "WEKO"}]}, {"creatorAlternatives": [{"creatorAlternative": "KUWANA, Syunichi", "creatorAlternativeLang": "en"}], "creatorNames": [{"creatorName": "桑名, 俊一", "creatorNameLang": "ja"}, {"creatorName": "KUWANA, Syunichi", "creatorNameLang": "en"}], "familyNames": [{"familyName": "クワナ", "familyNameLang": "ja"}], "givenNames": [{"givenName": "シュンイチ", "givenNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "496", "nameIdentifierScheme": "WEKO"}]}, {"creatorAlternatives": [{"creatorAlternative": "WATANABE, Akira", "creatorAlternativeLang": "en"}], "creatorNames": [{"creatorName": "渡邉, 章", "creatorNameLang": "ja"}, {"creatorName": "WATANABE, Akira", "creatorNameLang": "en"}], "familyNames": [{"familyName": "ワタナベ", "familyNameLang": "ja"}], "givenNames": [{"givenName": "アキラ", "givenNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "497", "nameIdentifierScheme": "WEKO"}]}, {"creatorAlternatives": [{"creatorAlternative": "TANAKA, Yuuji", "creatorAlternativeLang": "en"}], "creatorNames": [{"creatorName": "田中, 勇治", "creatorNameLang": "ja"}, {"creatorName": "TANAKA, Yuuji", "creatorNameLang": "en"}], "familyNames": [{"familyName": "ユウジ", "familyNameLang": "ja"}], "givenNames": [{"givenName": "タナカ", "givenNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "498", "nameIdentifierScheme": "WEKO"}]}, {"creatorAlternatives": [{"creatorAlternative": "MURAKAMI, Yoshiyuki", "creatorAlternativeLang": "en"}], "creatorNames": [{"creatorName": "村上, 仁之", "creatorNameLang": "ja"}, {"creatorName": "MURAKAMI, Yoshiyuki", "creatorNameLang": "en"}], "familyNames": [{"familyName": "ムラカミ", "familyNameLang": "ja"}], "givenNames": [{"givenName": "ヨシユキ", "givenNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "499", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-05-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00008523520.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_5", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "KJ00008523520.pdf", "url": "https://uekusa.repo.nii.ac.jp/record/291/files/KJ00008523520.pdf"}, "version_id": "3ba57de6-530d-4277-9d4e-2da643d199b1"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "入力デバイス", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "筋電", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "眼電", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "脳波", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Input device", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Electro Myogram", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Electro Oculogram", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Electro Encephalogram", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "障害(児)者を対象とした生体信号入力デバイスの適応の可能性について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "障害(児)者を対象とした生体信号入力デバイスの適応の可能性について", "subitem_title_language": "ja"}, {"subitem_title": "easibility of using a biological signals-based input device with disabled people, especially children", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "4", "path": ["1", "63"], "permalink_uri": "https://uekusa.repo.nii.ac.jp/records/291", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2017-05-26"}, "publish_date": "2017-05-26", "publish_status": "0", "recid": "291", "relation": {}, "relation_version_is_last": true, "title": ["障害(児)者を対象とした生体信号入力デバイスの適応の可能性について"], "weko_shared_id": -1}
障害(児)者を対象とした生体信号入力デバイスの適応の可能性について
https://uekusa.repo.nii.ac.jp/records/291
https://uekusa.repo.nii.ac.jp/records/2917074e5cf-cdc6-4949-9769-c179730fa70c
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00008523520.pdf (1.2 MB)
|
Item type | [ELS]紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-05-26 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 障害(児)者を対象とした生体信号入力デバイスの適応の可能性について | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | easibility of using a biological signals-based input device with disabled people, especially children | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 入力デバイス | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 筋電 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 眼電 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 脳波 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Input device | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Electro Myogram | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Electro Oculogram | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Electro Encephalogram | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12412714 | |||||
著者 |
宮坂, 智哉
× 宮坂, 智哉× 桑名, 俊一× 渡邉, 章× 田中, 勇治× 村上, 仁之 |
|||||
抄録(日) | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 近年,筋電,眼電,脳波などの生体信号を利用した入力デバイスが市販されている。それらが福祉機器の入力デバイスとして利用できれば,障害(児)者が入力デバイスを選定する選択肢が広がり,また社会福祉予算の効率的,効果的な活用が期待できる。本研究は,市販の生体信号入力デバイスを対象とし,障害(児)者を対象とした入力デバイスとしての適応の可能性を評価した。評価の実施には入力手段として咬合動作による筋電,眼球の外転,内転による眼電,脳波の3種類を対象とし,健常成人4名を被験者とした。結果として,3種類の入力手段のうち咬合動作による筋電については有効であった。一方眼電,脳波についての適応は困難だった。 | |||||
言語 | ja | |||||
抄録(英) | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In recent years, some input devices using biological signals - Electro Myogram (EMG), Electro Oculogram (EOG) and Electro Encephalogram (EEG) have become commercially available. There are indications that commercial use of these devices has great potential to increase the options of persons with disabilities as well as efficiently and effectively make use of the social welfare budget. We evaluated the feasible adaptability of one particular device as an assistive device for these individuals. Operation of the 3 biological input methods of the device – EMG, EOG and EEG was evaluated by 4people with non-disabilities. The results of the evaluation indicated that the input device using EMG had potential use as an assistive input device, while, those using EOG and EEG did not. | |||||
言語 | en | |||||
書誌情報 |
ja : 植草学園大学研究紀要 en : Bulletin of Education and Health Sciences, Uekusa-Gakuen University 巻 3, p. 121-127, ページ数 159, 発行日 2011-03-01 |
|||||
表示順 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 15 | |||||
アクセション番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | KJ00008523520 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 18835988 |