{"created":"2023-05-15T14:32:53.087463+00:00","id":291,"links":{},"metadata":{"_buckets":{"deposit":"bf21efc9-8e5a-47a5-b094-cf236f5b3153"},"_deposit":{"created_by":4,"id":"291","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"291"},"status":"published"},"_oai":{"id":"oai:uekusa.repo.nii.ac.jp:00000291","sets":["1","1:63"]},"author_link":["495","496","497","498","499"],"control_number":"291","item_3_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-03-01","bibliographicIssueDateType":"Issued"},"bibliographicNumberOfPages":"159","bibliographicPageEnd":"127","bibliographicPageStart":"121","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"植草学園大学研究紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Bulletin of Education and Health Sciences, Uekusa-Gakuen University","bibliographic_titleLang":"en"}]}]},"item_3_description_10":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"近年,筋電,眼電,脳波などの生体信号を利用した入力デバイスが市販されている。それらが福祉機器の入力デバイスとして利用できれば,障害(児)者が入力デバイスを選定する選択肢が広がり,また社会福祉予算の効率的,効果的な活用が期待できる。本研究は,市販の生体信号入力デバイスを対象とし,障害(児)者を対象とした入力デバイスとしての適応の可能性を評価した。評価の実施には入力手段として咬合動作による筋電,眼球の外転,内転による眼電,脳波の3種類を対象とし,健常成人4名を被験者とした。結果として,3種類の入力手段のうち咬合動作による筋電については有効であった。一方眼電,脳波についての適応は困難だった。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_3_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"In recent years, some input devices using biological signals - Electro Myogram (EMG), Electro Oculogram (EOG) and Electro Encephalogram (EEG) have become commercially available. There are indications that commercial use of these devices has great potential to increase the options of persons with disabilities as well as efficiently and effectively make use of the social welfare budget. We evaluated the feasible adaptability of one particular device as an assistive device for these individuals. Operation of the 3 biological input methods of the device – EMG, EOG and EEG was evaluated by 4people with non-disabilities. The results of the evaluation indicated that the input device using EMG had potential use as an assistive input device, while, those using EOG and EEG did not.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_3_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"15","subitem_description_type":"Other"}]},"item_3_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00008523520","subitem_description_type":"Other"}]},"item_3_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA12412714","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18835988","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAlternatives":[{"creatorAlternative":"MIYASAKA, Tomoya","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"宮坂, 智哉","creatorNameLang":"ja"},{"creatorName":"MIYASAKA, Tomoya","creatorNameLang":"en"}],"familyNames":[{"familyName":"ミヤサカ","familyNameLang":"ja"}],"givenNames":[{"givenName":"トモヤ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"495","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"KUWANA, Syunichi","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"桑名, 俊一","creatorNameLang":"ja"},{"creatorName":"KUWANA, Syunichi","creatorNameLang":"en"}],"familyNames":[{"familyName":"クワナ","familyNameLang":"ja"}],"givenNames":[{"givenName":"シュンイチ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"496","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"WATANABE, Akira","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"渡邉, 章","creatorNameLang":"ja"},{"creatorName":"WATANABE, Akira","creatorNameLang":"en"}],"familyNames":[{"familyName":"ワタナベ","familyNameLang":"ja"}],"givenNames":[{"givenName":"アキラ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"497","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"TANAKA, Yuuji","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"田中, 勇治","creatorNameLang":"ja"},{"creatorName":"TANAKA, Yuuji","creatorNameLang":"en"}],"familyNames":[{"familyName":"ユウジ","familyNameLang":"ja"}],"givenNames":[{"givenName":"タナカ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"498","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"MURAKAMI, Yoshiyuki","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"村上, 仁之","creatorNameLang":"ja"},{"creatorName":"MURAKAMI, Yoshiyuki","creatorNameLang":"en"}],"familyNames":[{"familyName":"ムラカミ","familyNameLang":"ja"}],"givenNames":[{"givenName":"ヨシユキ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"499","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-26"}],"displaytype":"detail","filename":"KJ00008523520.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_5","mimetype":"application/pdf","url":{"label":"KJ00008523520.pdf","url":"https://uekusa.repo.nii.ac.jp/record/291/files/KJ00008523520.pdf"},"version_id":"3ba57de6-530d-4277-9d4e-2da643d199b1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"入力デバイス","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"筋電","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"眼電","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"脳波","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"Input device","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electro Myogram","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electro Oculogram","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electro Encephalogram","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"障害(児)者を対象とした生体信号入力デバイスの適応の可能性について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"障害(児)者を対象とした生体信号入力デバイスの適応の可能性について","subitem_title_language":"ja"},{"subitem_title":"easibility of using a biological signals-based input device with disabled people, especially children","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["1","63"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-05-26"},"publish_date":"2017-05-26","publish_status":"0","recid":"291","relation_version_is_last":true,"title":["障害(児)者を対象とした生体信号入力デバイスの適応の可能性について"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-11-20T07:56:50.090757+00:00"}