{"created":"2023-05-15T14:32:50.383698+00:00","id":243,"links":{},"metadata":{"_buckets":{"deposit":"798917fe-0791-49ec-8bac-15ba0dd0f17a"},"_deposit":{"created_by":4,"id":"243","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"243"},"status":"published"},"_oai":{"id":"oai:uekusa.repo.nii.ac.jp:00000243","sets":["1","1:61"]},"author_link":["424","425","426","427","428","429"],"control_number":"243","item_3_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-03-01","bibliographicIssueDateType":"Issued"},"bibliographicNumberOfPages":"128","bibliographicPageEnd":"11","bibliographicPageStart":"5","bibliographicVolumeNumber":"1","bibliographic_titles":[{"bibliographic_title":"植草学園大学研究紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Bulletin of Education and Health Sciences, Uekusa-Gakuen University","bibliographic_titleLang":"en"}]}]},"item_3_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"4","subitem_description_type":"Other"}]},"item_3_description_16":{"attribute_name":"アクセション番号","attribute_value_mlt":[{"subitem_description":"KJ00010287259","subitem_description_type":"Other"}]},"item_3_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"神経筋疾患患者の意思fe達を支援する入カゲバイスは,介護者によって設置されることが多い。入カゲバイスの設置に時間がかかると介護負担は増加する。本研究では,介護者が容易に設置できる眼球連動入カゲバイスを開発した。開発した眼球連動入カゲバイス(新型機)は,眼球連動の検出に2つのモーションセンサを用い,アナログジョイスアィックでそれらの検出位置を可変する構成とした。一方研究者が以に開発した眼球連動入カゲバイス(從来型機)は,眼球連動の検出に画面上に固定した2つの光センサを用いたことで,検出位置は固定した構成たった。18名の健常成人を被験者とし,新型機と從来型機の設置時間を測定した。設置時間は新型機が55.8±27.2秒,從来型機は81.9 土58.7秒で,新型機は從来型機よりも設置時間を26秒短縮した。このことから,新型機の眼球連動入カゲバイスは從来型機よりも介護者の負担を軽減する可能性が得られた。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_3_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Input devices for patients with neuromuscular diseases are generally set up by their caregivers. Prolonged set up time of the devices often increase their caregiver burden. We have succeeded in developing an eye-operated communication device (new device) which can be simply installed. The new device detected eye movements by two motion sensors on the control unit whose positions could be moved by an analog joystick. In contrast, the conventional device that we had \ndeveloped, detected eye movements by two photo sensors that were fixed in place on the unit. The function and the installation times of each model were compared by 18 able-body subjects. It took 55.8±27.2s (new) and 81.9±58.7s (conventional) to set up each device. The installation time of the new device was reduced by 26sec compared to that of the conventional one. The new device with variable detection positions shortened the installation time. The shortened installation time of the device will directly reduce the burden on care givers.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_3_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA12412714","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18835988","subitem_source_identifier_type":"PISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAlternatives":[{"creatorAlternative":"MIYASAKA, Tomoya","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"宮坂, 智哉","creatorNameLang":"ja"},{"creatorName":"MIYASAKA, Tomoya","creatorNameLang":"en"}],"familyNames":[{"familyName":"ミヤサカ","familyNameLang":"ja"}],"givenNames":[{"givenName":"トモヤ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"424","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"WATANABE, Tomoyuki","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"渡邊, 智之","creatorNameLang":"ja"},{"creatorName":"WATANABE, Tomoyuki","creatorNameLang":"en"}],"familyNames":[{"familyName":"ワタナベ","familyNameLang":"ja"}],"givenNames":[{"givenName":"トモユキ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"425","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"HOTTA, Mamiko","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"堀田, 麻実子","creatorNameLang":"ja"},{"creatorName":"HOTTA, Mamiko","creatorNameLang":"en"}],"familyNames":[{"familyName":"ホッタ","familyNameLang":"ja"}],"givenNames":[{"givenName":"マミコ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"426","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"KIDO, Satoshi","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"木戸, 聡史","creatorNameLang":"ja"},{"creatorName":"KIDO, Satoshi","creatorNameLang":"en"}],"familyNames":[{"familyName":"キド","familyNameLang":"ja"}],"givenNames":[{"givenName":"サトシ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"427","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"YAMANAKA, Yuki","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"山中, 悠紀","creatorNameLang":"ja"},{"creatorName":"YAMANAKA, Yuki","creatorNameLang":"en"}],"familyNames":[{"familyName":"ヤマナカ","familyNameLang":"ja"}],"givenNames":[{"givenName":"ユキ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"428","nameIdentifierScheme":"WEKO"}]},{"creatorAlternatives":[{"creatorAlternative":"TANAKA, Toshiaki","creatorAlternativeLang":"en"}],"creatorNames":[{"creatorName":"田中, 敏明","creatorNameLang":"ja"},{"creatorName":"TANAKA, Toshiaki","creatorNameLang":"en"}],"familyNames":[{"familyName":"タナカ","familyNameLang":"ja"}],"givenNames":[{"givenName":"トシアキ","givenNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"429","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-26"}],"displaytype":"detail","filename":"KJ00010287259.pdf","filesize":[{"value":"306.7 kB"}],"format":"application/pdf","licensetype":"license_5","mimetype":"application/pdf","url":{"label":"KJ00010287259.pdf","url":"https://uekusa.repo.nii.ac.jp/record/243/files/KJ00010287259.pdf"},"version_id":"7cde6118-d04b-4963-9fde-15d2c7f2b759"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"神経筋疾患","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"眼球運動","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"入力デバイス","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"介護負担","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"neuromuscular disease","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"eye movement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"input device","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"care burden","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"神経筋疾患患者を対象とした眼球運動入力デバイスの開発と評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"神経筋疾患患者を対象とした眼球運動入力デバイスの開発と評価","subitem_title_language":"ja"},{"subitem_title":"The development and evaluation of an eye-operated communication device for patients with neuromuscular diseases","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["1","61"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-05-26"},"publish_date":"2017-05-26","publish_status":"0","recid":"243","relation_version_is_last":true,"title":["神経筋疾患患者を対象とした眼球運動入力デバイスの開発と評価"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-11-14T08:28:18.374864+00:00"}